1. Sensitivity The detector should be able to detect all types of explosives in vapour mode at room temperature

2. Selectivity System should not respond to odour of non explosive substance

3. Specificity False alarm rate should be less than 1%.

4. Detector Capability Should be able to detect all types of explosives including explosives with low vapour pressure explosives in mixture form

5. Carrier Gas Detector system should not require the use of carrier gas.

6. Auto Calibration Adjustment/Resetting for further operation should be automatic.

7. Warm up Time Should be less than 10 minutes.

8. Analysis Time Less than 6 seconds.

9. EMI Operation should not be affected by electro magnetic interference of other electronic/electrical devices.

10. Versatility Equipment should allow search of all places example Field Area automobiles, aircraft etc.

11. Ease of Operation Controls should be simple and easy to operate by bomb technician. Should not involve technician making or interpretation at the operator level, Grand Learn Capability.

12. Operating Temperature a) Minimum - (-) 10 degree Celsius b) Maximum - (+) 55 degree Celsius

13. Endurance On 230 V AC supply equipment should work continuously on battery, continuous operation should give more than 3 hours of operation.

14. Weight It should be one man portable and complete equipment should fit into one hand carrying case. Maximum operating weight should not exceed 4 Kgs.

15. Indication Both visual and audio alarm signal

16. Power Supply Should operate both on battery as well as external power source.

17. Safety The equipment should be safe to handle and be free from radiation hazards to the operator.

18. Mode Should be able to function both on vapour and particle mode.

19. Spares and Service User hand book, tech service manual, spares kit comprising of battery charger, test samples and spare battery should be provided with the equipment