Tender
> 2005-06 |
|
INDIA TRADE PROMOTION ORGANISATION
(A Government of India Enterprise)
Pragati Bhawan, Pragati Maidan,
New Delhi-110001.
Notice Inviting Tender
Tender No.ITPO: CD: AMC:BIC: 2007
Date : 14.3.2006
India Trade Promotion Organization, New Delhi
invites technical and commercial bids from authorized/experienced
companies for annual maintenance contract for 1 No. 15 KVA UPS installed
in Business Information Centre, Hall No.19, Pragati Maidan, and
New Delhi for a period of three years.
Technical Specifications
| Make of UPS |
CONSUL - MEGALINE |
| Physical dimensions of the UPS and weight of the UPS |
(H*W*D in mm) = (1150*820*630) approx.
Weight = 275 Kgs.(UPS only)
|
| Make and AH of batteries |
Exide Power/AH is 12V* 28AH *30 Nos. for computer load |
| Physical dimension of battery rack |
(H*W*D in mm) = (650*350*400) approx. |
| Capacity |
15 KVA UPS (Three Phase input and three phase output) |
| AC Input (3 phase, 4 Wire) |
415 V + 15% to 20% @ 50Hz +/-3 Hz |
| AC output (single phase) |
|
| Rating |
Continuous |
| Voltage |
415 V +/-1% |
| Frequency |
50 Hz+ 0.1 Hz |
| Wave from |
Pure sine wave |
| Inverter Technology |
High frequency (25KHz) PWM using microprocessor controlled
IGBTs |
| Transient Response & Recovery |
For 100% step load, change in output volt not exceeding
8% and recovery within 3 cycles |
| Inverter Efficiency |
> 91% - 94% at full load |
| THD |
<3% on linear & complex load |
| Load Power Factor |
0.8 |
| Over load |
120% for 10 mins. (can be software programmed for longer
duration, however is strictly temperature controlled)
150% for 5 Mins.
200% for 0.3 Secs.
|
| Crest Factor |
3 : 1 |
| Metering |
The software provided alongwith CONSUL-MEGALINE |
| |
UPS can monitor the following parameters such as Output
Voltage, Current, Temperature, Power level etc. Upto 16 parameters
can be monitored. The software is extremely user friendly
and very easy to operate. |
| Indications |
LED display for Mains On, Inverter Over Load, Inverter On,
Mains Fail Alarm, By-Pass Alarm, Battery Low Alarm, Self Test,
RMS Load Alarm, Peak Load Temperature, Load on By-Pass. |
| Protections |
3 Phase input MCB, over load inverter trip, under voltage
inverter trip, over voltage inverter trip, battery charging
current limit, short circuit inverter trip |
| Soft Start |
Both available on charger and inverter |
| Alarm |
Buzzer for battery low |
| Isolation |
Galvanic Isolation provided |
Technical
1. The firm/company should be in existence for over 5 years in the
trade with the maintenance business having service business turn
over of more than Rs.20 lakhs per annum during the last 2 years
ending March 31, 2007.
2. The firm/company should have a previous maintenance contract
for at least two years with a Government Department/Public Sector
Undertaking in Delhi. The company should furnish statement of
previous work for the last two years.
3. The firm/company must have expertise in on-site maintenance
and repair of UPS.
4. The firm/company should be authorized service provider/a business
partner of leading UPS manufacturers. Please attach a copy of
valid service authorization certificate from the manufacturer.
5. The firm/company should produce copies of documents relating
to allocation of service tax registration number VAT registration
number and PAN number.
6. The firm/company should submit a draft of Rs.4,500/- towards
earnest money deposit
Financial
1. The rate may be quoted on annual basis for UPS in a separate
sealed cover.
2. The other terms & conditions for awarding the AMC shall be
as follows:
" The AMC will be applicable for a period of 3 years from the
date of signing of the contract.
" The comprehensive maintenance includes preventive maintenance,
quarterly regular services of the UPS, etc. and/or replacement of
any items necessary for keeping the 15 KVA UPS active and free from
any defects or disturbance and also on any unscheduled call for
corrective and maintenance services, taking appropriate measures/steps
on time to set right the malfunctioning of the UPS. The replacement
of all the spares including batteries, etc. is included under the
maintenance contract. The replacement of defective spares with original
spares or spares of equivalent specification will be done by the
AMC company, without any extra charge of any kind.
" The AMC charges will be payable at the end of each year based
on satisfactory services for the quarter.
" All taxes - VAT, octroi, service tax, etc. - if any, should
be included in the prices quoted for the AMC.
" Quotes should cover quarterly preventive maintenance and
when called for in the event of break-down.
" Please quote service tax registration no., VAT registration
no. and PAN no. in your offer.
" The jurisdiction in case of disputes shall be the courts
of Delhi/New Delhi.
" ITPO can accept or reject any offer at its discretion without
assigning any reason, whatsoever.
The tender documents
can be collected in person on payment of Rs.500/- (non refundable)
in cash or by way of demand draft of the said amount favouring India
Trade Promotion Organisation payable at New Delhi. Tender form can
be downloaded from our website:www.indiatradefair.com and the tender
cost deposited alongwith the bid by way of demand draft. The last
date for sale of tender document is 20.3.2007.
Technical and commercial bids
are required to be submitted separately in sealed covers marked
"QUOTATIONS FOR AMC FOR 15 KVA UPS FOR BIC" written on
the envelope and sent to Mrs. S. Swami, Sr. Manager, Computer Department,
India Trade Promotion Orgnaisation, Ground Floor, Pragati Bhawan
(Annexe II), Pragati Maidan, New Delhi-110 001, latest by 29.3.2007
upto 3.00PM.. The Technical bids will be opened on the same date
at 3.30PM. The intimation for opening of Financial Bids of only
successful Technical Bidder will be communicated separately.
|
| |
Pragati Bhawan, Pragati Maidan, New Delhi-110 001,
E-mail : info@itpo-online.com
|
|